Objective: To compare early and midterm outcomes of transcatheter valve-in-valve implantation (ViV-TAVI) and redo surgical aortic valve replacement (re-SAVR) for aortic bioprosthetic valve degeneration. Design: Patients who underwent ViV-TAVI and re-SAVR for aortic bioprosthetic valve degeneration between January 2010 and October 2018 were retrospectively analyzed. Mean follow-up was 3.0 years. Setting: In-hospital, early, and mid-term outcomes. Participants: Eighty-eight patients were included in the analysis. Interventions: Thirty-one patients (37.3%) had ViV-TAVI, and 57 patients (62.7%) had re-SAVR. Measurements and Main Results: In the ViV-TAVI group, patients were older (79.1 ± 7.4 v 67.2 ± 14.1, p < 0.01). The total operative time, intubation time, intensive care unit length of stay, total hospital length of stay, inotropes infusion, intubation >24 hours, total amount of chest tube losses, red blood cell transfusions, plasma transfusions, and reoperation for bleeding were significantly higher in the re-SAVR cohort (p < 0.01). There was no difference regarding in-hospital permanent pacemaker implantation (ViV-TAVI = 3.2% v re-SAVR = 8.8%, p = 0.27), patient-prosthesis mismatch (ViV-TAVI = 12 patients [mean 0.53 ± 0.07] and re-SAVR = ten patients [mean 0.56 ± 0.08], p = 0.4), stroke (ViV-TAVI = 3.2% v re-SAVR = 7%, p = 0.43), acute kidney injury (ViV-TAVI = 9.7% v re-SAVR = 15.8%, p = 0.1), and all-cause infections (ViV-TAVI = 0% v re-SAVR = 8.8%, p = 0.02), between the two groups. In-hospital mortality was 0% and 7% for ViV-TAVI and re-SAVR, respectively (p = 0.08). At three-years’ follow-up, the incidence of pacemaker implantation was higher in the re-SAVR group (ViV-TAVI = 0 v re-SAVR = 13.4%, p < 0.01). There were no differences in reintervention (ViV-TAVI = 3.8% v re-SAVR = 0%, p = 0.32) and survival (ViV-TAVI = 83.9% v re-SAVR = 93%, p = 0.10) between the two cohorts. Conclusions: ViV-TAVI is a safe, feasible, and reliable procedure.

Dokollari, A., Cameli, M., Mandoli, G.E., Kalra, D.-.S., Poston, R., Coku, L., et al. (2021). Early and Midterm Clinical Outcomes of Transcatheter Valve-in-Valve Implantation Versus Redo Surgical Aortic Valve Replacement for Aortic Bioprosthetic Valve Degeneration: Two Faces of the Same Medal. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 35(11), 3223-3231 [10.1053/j.jvca.2021.05.029].

Early and Midterm Clinical Outcomes of Transcatheter Valve-in-Valve Implantation Versus Redo Surgical Aortic Valve Replacement for Aortic Bioprosthetic Valve Degeneration: Two Faces of the Same Medal

Cameli M.;Mandoli G. E.;
2021-01-01

Abstract

Objective: To compare early and midterm outcomes of transcatheter valve-in-valve implantation (ViV-TAVI) and redo surgical aortic valve replacement (re-SAVR) for aortic bioprosthetic valve degeneration. Design: Patients who underwent ViV-TAVI and re-SAVR for aortic bioprosthetic valve degeneration between January 2010 and October 2018 were retrospectively analyzed. Mean follow-up was 3.0 years. Setting: In-hospital, early, and mid-term outcomes. Participants: Eighty-eight patients were included in the analysis. Interventions: Thirty-one patients (37.3%) had ViV-TAVI, and 57 patients (62.7%) had re-SAVR. Measurements and Main Results: In the ViV-TAVI group, patients were older (79.1 ± 7.4 v 67.2 ± 14.1, p < 0.01). The total operative time, intubation time, intensive care unit length of stay, total hospital length of stay, inotropes infusion, intubation >24 hours, total amount of chest tube losses, red blood cell transfusions, plasma transfusions, and reoperation for bleeding were significantly higher in the re-SAVR cohort (p < 0.01). There was no difference regarding in-hospital permanent pacemaker implantation (ViV-TAVI = 3.2% v re-SAVR = 8.8%, p = 0.27), patient-prosthesis mismatch (ViV-TAVI = 12 patients [mean 0.53 ± 0.07] and re-SAVR = ten patients [mean 0.56 ± 0.08], p = 0.4), stroke (ViV-TAVI = 3.2% v re-SAVR = 7%, p = 0.43), acute kidney injury (ViV-TAVI = 9.7% v re-SAVR = 15.8%, p = 0.1), and all-cause infections (ViV-TAVI = 0% v re-SAVR = 8.8%, p = 0.02), between the two groups. In-hospital mortality was 0% and 7% for ViV-TAVI and re-SAVR, respectively (p = 0.08). At three-years’ follow-up, the incidence of pacemaker implantation was higher in the re-SAVR group (ViV-TAVI = 0 v re-SAVR = 13.4%, p < 0.01). There were no differences in reintervention (ViV-TAVI = 3.8% v re-SAVR = 0%, p = 0.32) and survival (ViV-TAVI = 83.9% v re-SAVR = 93%, p = 0.10) between the two cohorts. Conclusions: ViV-TAVI is a safe, feasible, and reliable procedure.
2021
Dokollari, A., Cameli, M., Mandoli, G.E., Kalra, D.-.S., Poston, R., Coku, L., et al. (2021). Early and Midterm Clinical Outcomes of Transcatheter Valve-in-Valve Implantation Versus Redo Surgical Aortic Valve Replacement for Aortic Bioprosthetic Valve Degeneration: Two Faces of the Same Medal. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 35(11), 3223-3231 [10.1053/j.jvca.2021.05.029].
File in questo prodotto:
File Dimensione Formato  
Valveinvalve vs redo aortic.pdf

accesso aperto

Tipologia: PDF editoriale
Licenza: Creative commons
Dimensione 676.89 kB
Formato Adobe PDF
676.89 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/1178930