Keratoconus (KC) is the most common degenerative corneal disease and no single biomarker for KC has been discovered. Its causes have not yet been clarified and this work aims to be a contribution to the deepening of the knowledge of this disease and a preliminary data to the evaluation of the possibility of the use of copper (Cu) concentration in the tear fluid as a specific marker. A tear fluid sampling and Cu determination by spectrometric atomic absorption method was optimized to determine Cu levels in the tear fluid of patients with KC compared to that of healthy patients. Results demonstrate that in the KC subjects (n=6) the concentration of Cu ions was 325.5 ± 110.7 ng/ml, while in the control group was 141.3 ± 71.1 ng/ml. A significant increase in Cu ion levels in the tear fluid was observed in the KC group compared to the control group (p value < 0.001).
Corbini, G., Dreassi, E., Chiasserini, L., Girolamo, M.M., Mellace, P. (2021). Determination of copper by AAS in tear fluid of patients with keratoconus. ANALYTICAL BIOCHEMISTRY, 623 [10.1016/j.ab.2021.114174].
Determination of copper by AAS in tear fluid of patients with keratoconus
Gianfranco Corbini
Conceptualization
;Elena DreassiData Curation
;Luisa ChiasseriniFormal Analysis
;Matteo Maria GirolamoFormal Analysis
;Pierfrancesco MellaceConceptualization
2021-01-01
Abstract
Keratoconus (KC) is the most common degenerative corneal disease and no single biomarker for KC has been discovered. Its causes have not yet been clarified and this work aims to be a contribution to the deepening of the knowledge of this disease and a preliminary data to the evaluation of the possibility of the use of copper (Cu) concentration in the tear fluid as a specific marker. A tear fluid sampling and Cu determination by spectrometric atomic absorption method was optimized to determine Cu levels in the tear fluid of patients with KC compared to that of healthy patients. Results demonstrate that in the KC subjects (n=6) the concentration of Cu ions was 325.5 ± 110.7 ng/ml, while in the control group was 141.3 ± 71.1 ng/ml. A significant increase in Cu ion levels in the tear fluid was observed in the KC group compared to the control group (p value < 0.001).File | Dimensione | Formato | |
---|---|---|---|
Determination of copper-Corbini-2021.pdf
non disponibili
Descrizione: Articolo
Tipologia:
PDF editoriale
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
516.1 kB
Formato
Adobe PDF
|
516.1 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11365/1134946