Single-photon avalanche diode (SPAD) arrays fabricated in a 180-nm CMOS technology with a high-voltage option have been exposed to calibrated neutron and X-ray sources to evaluate their radiation tolerance. The technology is being investigated in view of the design of low material budget detectors for charged particle tracking based on the coincidence of the signals coming from two or more overlapping layers of SPAD sensors. Each element in the array is a monolithic detector including the processing electronics together with the diode in the same substrate. Different sensor dimensions and structures have been implemented in the test chip to thoroughly explore the technology features. This paper will present and discuss the results from the characterization, in terms of dark count rate, of SPAD arrays irradiated with X-ray doses reaching 1 Mrad(SiO2) and with neutron fluences up to 10(11) 1-MeV neutron equivalent cm(-2).

Ratti, L., Brogi, P., Collazuol, G., Dalla Betta, G.-., Ficorella, A., Lodola, L., et al. (2019). Dark Count Rate Degradation in CMOS SPADs Exposed to X-Rays and Neutrons. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 66(2), 567-574 [10.1109/TNS.2019.2893233].

Dark Count Rate Degradation in CMOS SPADs Exposed to X-Rays and Neutrons

Brogi, P.;Marrocchesi, P. S.;
2019-01-01

Abstract

Single-photon avalanche diode (SPAD) arrays fabricated in a 180-nm CMOS technology with a high-voltage option have been exposed to calibrated neutron and X-ray sources to evaluate their radiation tolerance. The technology is being investigated in view of the design of low material budget detectors for charged particle tracking based on the coincidence of the signals coming from two or more overlapping layers of SPAD sensors. Each element in the array is a monolithic detector including the processing electronics together with the diode in the same substrate. Different sensor dimensions and structures have been implemented in the test chip to thoroughly explore the technology features. This paper will present and discuss the results from the characterization, in terms of dark count rate, of SPAD arrays irradiated with X-ray doses reaching 1 Mrad(SiO2) and with neutron fluences up to 10(11) 1-MeV neutron equivalent cm(-2).
2019
Ratti, L., Brogi, P., Collazuol, G., Dalla Betta, G.-., Ficorella, A., Lodola, L., et al. (2019). Dark Count Rate Degradation in CMOS SPADs Exposed to X-Rays and Neutrons. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 66(2), 567-574 [10.1109/TNS.2019.2893233].
File in questo prodotto:
File Dimensione Formato  
searchcalet.pdf

accesso aperto

Tipologia: Pre-print
Licenza: PUBBLICO - Pubblico con Copyright
Dimensione 505.62 kB
Formato Adobe PDF
505.62 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/1073276