BACKGROUND: A dialyzed patient weekly gets in touch with a large amount of water (on average 350 liters) through the dialysis bath. It is therefore essential that this solution would have a high quality and purity. The aim of our study was to monitor the microbiological quality of the hemodialysis water in order to identify possible factors that could affect it. METHODS: We conducted a cross-sectional study from January 2015 to October 2017 collecting the dialysis water in AOU Careggi. Samples were aseptically collected by specialized technicians and then transported under ice at 4° C to the Laboratory of Biological Hazards of USL Toscana Centro for laboratory analyses. RESULTS: 126 water samples were collected. Coliforms, E. coli, Staphylococcus aureus, enterococci were not detected. Pseudomonas aeruginosa was found in only one sample. Both for CFU at 37° C and at 22° C, the type of device represented the only statistically significant risk factor (OR 15.21 and OR 10.25 respectively): SDS devices had a significantly higher risk of being positive for CFU at 37° C and 22° C. CONCLUSIONS: As our study demonstrated, the system producing dialysis water must be constantly monitored, especially in cases of SDS devices which may be subjected more frequently to a higher contamination, due to their discontinuous use. Copyright by Società Italiana di Nefrologia SIN, Rome, Italy.
Introduzione Un paziente in dialisi entra in contatto settimanalmente con un’ingente quantità d’acqua tramite il bagno di dialisi, in media 350 litri. È pertanto essenziale che questa soluzione abbia un’elevata qualità e purezza. Scopo del nostro studio è stato monitorare nel tempo la qualità microbiologica delle acque dell’emodialisi, al fine di individuare eventuali fattori che possano influenzarla. Metodi Abbiamo effettuato da Gennaio 2015 a Ottobre 2017 uno studio cross-sectional raccogliendo le acque delle apparecchiature dialitiche presso l’AOU Careggi. I campioni raccolti in maniera asettica e da tecnici specializzati, sono stati trasportati sotto ghiaccio a 4°C al Laboratorio di Rischio Biologico dell’Azienda USL Toscana Centro per le analisi di laboratorio. Risultati Sono stati raccolti 126 campioni di acqua. Coliformi, E. coli, Staphylococcus aureus, enterococchi sono risultati negativi in tutti i campioni. Pseudomonas aeruginosa è risultata positiva in un solo campione. Sia per le CFU a 37°C che a 22°C la tipologia di macchinario rappresenta l’unico fattore di rischio statisticamente significativo (OR 15.21 e OR 10.25 rispettivamente): i macchinari SDS hanno un rischio decisamente più alto di risultare positivi per le CFU a 37°C e 22°C. Conclusioni È necessario monitorare costantemente il sistema di trattamento delle acque di dialisi e questo ancor più nel caso di dispositivi con sistema SDS che, a causa del loro utilizzo discontinuo, possono essere soggetti più frequentemente, come dimostrato nel nostro studio, a maggiore contaminazione. PAROLE CHIAVE: sorveglianza, emodialisi, infezioni
46) Troiano, G., Messina, G., Zanieri, E., Li Donni, V., Nante, N., Magisteri, L., et al. (2018). Qualità microbiologica delle acque per emodialisi: quali i fattori di rischio? [Microbiological quality of hemodialysis water: what are the risk factors?]. GIORNALE ITALIANO DI NEFROLOGIA, 35(5), 141-147.
Qualità microbiologica delle acque per emodialisi: quali i fattori di rischio? [Microbiological quality of hemodialysis water: what are the risk factors?]
Messina G.;Nante N.;
2018-01-01
Abstract
BACKGROUND: A dialyzed patient weekly gets in touch with a large amount of water (on average 350 liters) through the dialysis bath. It is therefore essential that this solution would have a high quality and purity. The aim of our study was to monitor the microbiological quality of the hemodialysis water in order to identify possible factors that could affect it. METHODS: We conducted a cross-sectional study from January 2015 to October 2017 collecting the dialysis water in AOU Careggi. Samples were aseptically collected by specialized technicians and then transported under ice at 4° C to the Laboratory of Biological Hazards of USL Toscana Centro for laboratory analyses. RESULTS: 126 water samples were collected. Coliforms, E. coli, Staphylococcus aureus, enterococci were not detected. Pseudomonas aeruginosa was found in only one sample. Both for CFU at 37° C and at 22° C, the type of device represented the only statistically significant risk factor (OR 15.21 and OR 10.25 respectively): SDS devices had a significantly higher risk of being positive for CFU at 37° C and 22° C. CONCLUSIONS: As our study demonstrated, the system producing dialysis water must be constantly monitored, especially in cases of SDS devices which may be subjected more frequently to a higher contamination, due to their discontinuous use. Copyright by Società Italiana di Nefrologia SIN, Rome, Italy.File | Dimensione | Formato | |
---|---|---|---|
46.pdf
non disponibili
Tipologia:
PDF editoriale
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
546.36 kB
Formato
Adobe PDF
|
546.36 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11365/1061423