Nanowire-based field-effect transistors (FETs) can be used as ultra-sensitive and label-free biosensors for detecting protein-protein interactions. A way to increase the performance of such sensors is to dilute the sensing buffer drastically. However, we show here that this can have an important effect on the function of the proteins. Moreover, it is demonstrated that this dilution significantly affects the pH stability of the sensing buffer, which consequently impacts the charge of the protein and thus the response and signal-to-noise ratio in the sensing experiments. Three model systems are investigated experimentally to illustrate the impact on ligand-protein and protein-protein interactions. Simulations are performed to illustrate the effect on the performance of the sensors. Combining various parameters, the current study provides a means for evaluating and selecting the most appropriate buffer composition for bioFET measurements. © 2013 IOP Publishing Ltd.
Lloret, N., Frederiksen, R.S., Møller, T.C., Rieben, N.I., Upadhyay, S., De Vico, L., et al. (2013). Effects of buffer composition and dilution on nanowire field-effect biosensors. NANOTECHNOLOGY, 24(3) [10.1088/0957-4484/24/3/035501].
Effects of buffer composition and dilution on nanowire field-effect biosensors
De Vico, Luca;
2013-01-01
Abstract
Nanowire-based field-effect transistors (FETs) can be used as ultra-sensitive and label-free biosensors for detecting protein-protein interactions. A way to increase the performance of such sensors is to dilute the sensing buffer drastically. However, we show here that this can have an important effect on the function of the proteins. Moreover, it is demonstrated that this dilution significantly affects the pH stability of the sensing buffer, which consequently impacts the charge of the protein and thus the response and signal-to-noise ratio in the sensing experiments. Three model systems are investigated experimentally to illustrate the impact on ligand-protein and protein-protein interactions. Simulations are performed to illustrate the effect on the performance of the sensors. Combining various parameters, the current study provides a means for evaluating and selecting the most appropriate buffer composition for bioFET measurements. © 2013 IOP Publishing Ltd.File | Dimensione | Formato | |
---|---|---|---|
0957-4484_24_3_035501.pdf
non disponibili
Descrizione: Articolo principale
Tipologia:
PDF editoriale
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
801.37 kB
Formato
Adobe PDF
|
801.37 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11365/1006802
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo