In this paper a Simulation Before Test diagnosis technique for detection of single and double faults in gas turbines is presented. Fault localization is performed by comparing the behavior of turbine under test with simulation data by means of a neural network algorithm. The technique is adaptable to operating and environmental conditions.
Catelani, M., Fort, A., Grande, V., Mugnaini, M., Trotta, I. (2006). Automatic Fault Diagnosis System for a Gas Turbine using a Simulation before Test Approach. In Instrumentation and Measurement Technology Conference Proceedings (pp.86-89). New York : IEEE [10.1109/IMTC.2006.235663].
Automatic Fault Diagnosis System for a Gas Turbine using a Simulation before Test Approach
Catelani, Marcantonio;Fort, Ada;Mugnaini, Marco;
2006-01-01
Abstract
In this paper a Simulation Before Test diagnosis technique for detection of single and double faults in gas turbines is presented. Fault localization is performed by comparing the behavior of turbine under test with simulation data by means of a neural network algorithm. The technique is adaptable to operating and environmental conditions.File | Dimensione | Formato | |
---|---|---|---|