The Cosmic Ray Energetics And Mass (CREAM) balloon-bome experiment, designed to directly measure cosmic-ray particle energies from similar to 10(11) to similar to 10(15) eV, had two successful flights since December 2004, with a total duration of 70 days. The CREAM calorimeter is comprised of 20 layers of 1 radiation length (X-0) tungsten interleaved with 20 active layers each made up of fifty 1 cm wide scintillating fiber ribbons. The scintillation signals are read out with multi pixel Hybrid Photo Diodes (HPDs), VA32-HDR2/TA32C ASICs and LTC1400 ADCs. During detector construction, various tests were carried out using radioactive sources, UV-LEDs, and particle beams. We will present results from these tests and show preliminary results from the two flights.

M. H., L., H. S., A., P., A., M. G., B., L., B., J. J., B., et al. (2006). The CREAM calorimeter: Performance in tests and flights. In Calorimetry in High Energy Physics (pp.167-174). 2 HUNTINGTON QUADRANGLE, STE 1NO1, MELVILLE, NY 11747-4501 USA : Amer Inst Physics [10.1063/1.2396951].

The CREAM calorimeter: Performance in tests and flights

BIGONGIARI, GABRIELE;MAESTRO, PAOLO;MARROCCHESI, PIER SIMONE;
2006-01-01

Abstract

The Cosmic Ray Energetics And Mass (CREAM) balloon-bome experiment, designed to directly measure cosmic-ray particle energies from similar to 10(11) to similar to 10(15) eV, had two successful flights since December 2004, with a total duration of 70 days. The CREAM calorimeter is comprised of 20 layers of 1 radiation length (X-0) tungsten interleaved with 20 active layers each made up of fifty 1 cm wide scintillating fiber ribbons. The scintillation signals are read out with multi pixel Hybrid Photo Diodes (HPDs), VA32-HDR2/TA32C ASICs and LTC1400 ADCs. During detector construction, various tests were carried out using radioactive sources, UV-LEDs, and particle beams. We will present results from these tests and show preliminary results from the two flights.
2006
0735403643
M. H., L., H. S., A., P., A., M. G., B., L., B., J. J., B., et al. (2006). The CREAM calorimeter: Performance in tests and flights. In Calorimetry in High Energy Physics (pp.167-174). 2 HUNTINGTON QUADRANGLE, STE 1NO1, MELVILLE, NY 11747-4501 USA : Amer Inst Physics [10.1063/1.2396951].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/43283