Aim. The shaping capacity of NiTi rotary instruments is often assessed by photographic or micro-CT measurements, and these instruments are often used more than once clinically. This study was conducted to compare photographic and micro-computed tomography (micro-CT) measurements and to assess if repeated use of NiTi instruments affected the shape of canal preparation. Methods.Ten new sets of ProTaper Universal instruments were used in 60 resin blocks simulating curved root canals. Groups 1 to 6 (n=10) represented 1st to 6th use of the instrument, respectively. Digitized images of the prepared blocks were taken in both mesiodistal (MD) and buccolingual (BL) directions and area measurements (mm2) were calculated using AutoCAD. The volumes of the same prepared canals were measured using micro-CT (mm3). Statistical analysis was performed to detect differences between photographic and volumetric measurements, and differences between uses. Results. Two-way repeated measures ANOVA revealed significant differences between groups (p<0.001). Regarding measurement type, there were no significant differences between BL and MD measurements, but there were significant differences between micro-CT and BL (p<0.001) and micro-CT and MD (p=0.001). Significant differences were also noted between uses. Conclusions. Within the limitations of the present study, micro-CT is more discriminative of the changes in canal space associated with repeated instrument use than photographic measurements. Canal preparations are significantly smaller after the third use of the same instrument.

Franciosi, ., Paragliola, R., Ounsi, H., Grandini, S. (2011). Comparison of two techniques for assessing the shaping efficacy of repeatedly-used NiTi rotary. In Atti del Congresso del collegio dei docenti di discipline odontostomatologiche. Siena-Firenze 14-16 Aprile 20.

Comparison of two techniques for assessing the shaping efficacy of repeatedly-used NiTi rotary

R. Paragliola;GRANDINI, SIMONE
2011-01-01

Abstract

Aim. The shaping capacity of NiTi rotary instruments is often assessed by photographic or micro-CT measurements, and these instruments are often used more than once clinically. This study was conducted to compare photographic and micro-computed tomography (micro-CT) measurements and to assess if repeated use of NiTi instruments affected the shape of canal preparation. Methods.Ten new sets of ProTaper Universal instruments were used in 60 resin blocks simulating curved root canals. Groups 1 to 6 (n=10) represented 1st to 6th use of the instrument, respectively. Digitized images of the prepared blocks were taken in both mesiodistal (MD) and buccolingual (BL) directions and area measurements (mm2) were calculated using AutoCAD. The volumes of the same prepared canals were measured using micro-CT (mm3). Statistical analysis was performed to detect differences between photographic and volumetric measurements, and differences between uses. Results. Two-way repeated measures ANOVA revealed significant differences between groups (p<0.001). Regarding measurement type, there were no significant differences between BL and MD measurements, but there were significant differences between micro-CT and BL (p<0.001) and micro-CT and MD (p=0.001). Significant differences were also noted between uses. Conclusions. Within the limitations of the present study, micro-CT is more discriminative of the changes in canal space associated with repeated instrument use than photographic measurements. Canal preparations are significantly smaller after the third use of the same instrument.
2011
Franciosi, ., Paragliola, R., Ounsi, H., Grandini, S. (2011). Comparison of two techniques for assessing the shaping efficacy of repeatedly-used NiTi rotary. In Atti del Congresso del collegio dei docenti di discipline odontostomatologiche. Siena-Firenze 14-16 Aprile 20.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/36903
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo