Purpose To assess the usefulness of optical coherence tomography (OCT) for better diff erential diagnosis of macular holes in comparison with biomicroscopical fundus analysis. Methods We reviewed the fi les of 25 eyes of 24 patients who were diagnosed as having a macular hole on OCT examination and biomicroscopical fundus analysis. Each eye underwent six radial 3-mm OCT scans centered on the macula, one 6-mm vertical and one 6-mm horizontal scan. Retinal thickness was measured at the foveal center and 750 &m from the center, vertically, and horizontally. " e diameter of the macular contour was also measured on vertical and horizontal scans. Results On biomicroscopy only 8 eyes (32%) were diagnosed as having macular hole, while in the remaining 17 eyes (68%) diagnosis of macular hole was possible only performing an OCT examination. Conclusion Optical coherence tomography is very useful in the diagnosis of macular holes compared with classic biomicroscopical analysis

Fruschelli, M., Motolese, I., Motolese, P.a., Frezzotti, P., Motolese, E. (2009). Optical coherence tomography and biomicroscopical analysis inmacular holes. ACTA OPHTHALMOLOGICA, 87 s244, 43-43 [10.1111/j.1755-3768.2009.2215.x].

Optical coherence tomography and biomicroscopical analysis inmacular holes

FRUSCHELLI, MARIO;MOTOLESE, ILARIA;FREZZOTTI, PAOLO;MOTOLESE, EDUARDO
2009-01-01

Abstract

Purpose To assess the usefulness of optical coherence tomography (OCT) for better diff erential diagnosis of macular holes in comparison with biomicroscopical fundus analysis. Methods We reviewed the fi les of 25 eyes of 24 patients who were diagnosed as having a macular hole on OCT examination and biomicroscopical fundus analysis. Each eye underwent six radial 3-mm OCT scans centered on the macula, one 6-mm vertical and one 6-mm horizontal scan. Retinal thickness was measured at the foveal center and 750 &m from the center, vertically, and horizontally. " e diameter of the macular contour was also measured on vertical and horizontal scans. Results On biomicroscopy only 8 eyes (32%) were diagnosed as having macular hole, while in the remaining 17 eyes (68%) diagnosis of macular hole was possible only performing an OCT examination. Conclusion Optical coherence tomography is very useful in the diagnosis of macular holes compared with classic biomicroscopical analysis
2009
Fruschelli, M., Motolese, I., Motolese, P.a., Frezzotti, P., Motolese, E. (2009). Optical coherence tomography and biomicroscopical analysis inmacular holes. ACTA OPHTHALMOLOGICA, 87 s244, 43-43 [10.1111/j.1755-3768.2009.2215.x].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/33458
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo