The Cosmic Ray Energetics And Mass (CREAM) balloon experiment had two successful flights in 2004/05 and 2005/06. It was designed to perform energy measurements from a few GeV up to 1000 TeV, taking advantage of different detection techniques. The first instrument, CREAM-1, combined a transition radiation detector with a calorimeter to provide independent energy measurements of cosmicray nuclei. Each detector was calibrated with particle beams in a limited range of energies. In order to assess the absolute energy scale of the instrument and to investigate the systematic effects of each technique, a cross-calibration was performed by comparing the two independent energy estimates on selected samples of oxygen and carbon nuclei.

Maestro, P., H. S., A., P., A., Bagliesi, M.G., J. J., B., Bigongiari, G., et al. (2008). Energy cross-calibration from the first CREAM flight: transition radiation detector versus calorimeter. In Proceedings of the 30th International Cosmic Ray Conference (pp.333-336). Merida : Universidad Nacional Autónoma de México.

Energy cross-calibration from the first CREAM flight: transition radiation detector versus calorimeter

MAESTRO, PAOLO;BAGLIESI, MARIA GRAZIA;BIGONGIARI, GABRIELE;MARROCCHESI, PIER SIMONE;ZEI, RICCARDO;
2008-01-01

Abstract

The Cosmic Ray Energetics And Mass (CREAM) balloon experiment had two successful flights in 2004/05 and 2005/06. It was designed to perform energy measurements from a few GeV up to 1000 TeV, taking advantage of different detection techniques. The first instrument, CREAM-1, combined a transition radiation detector with a calorimeter to provide independent energy measurements of cosmicray nuclei. Each detector was calibrated with particle beams in a limited range of energies. In order to assess the absolute energy scale of the instrument and to investigate the systematic effects of each technique, a cross-calibration was performed by comparing the two independent energy estimates on selected samples of oxygen and carbon nuclei.
2008
Maestro, P., H. S., A., P., A., Bagliesi, M.G., J. J., B., Bigongiari, G., et al. (2008). Energy cross-calibration from the first CREAM flight: transition radiation detector versus calorimeter. In Proceedings of the 30th International Cosmic Ray Conference (pp.333-336). Merida : Universidad Nacional Autónoma de México.
File in questo prodotto:
File Dimensione Formato  
icrc309.pdf

non disponibili

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 179.5 kB
Formato Adobe PDF
179.5 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/30972