The aim of this paper is to discuss the usability of Long Range (LoRa) communication technology for the transmission of data collected under fresh water to a Gateway positioned outside water. The technical feasibility of the LoRa transmission channel is discussed from a theoretical point of view, focusing on the definition of the link budget for the proposed scenario. The operation of a prototypal LoRa sensor node is then tested in a real scenario, analyzing the performances according to the different Spreading Factors (SF). Actual data transmission is achieved at a depth of 30 cm, thus suggesting the usage of such a technology for real time monitoring applications in environments, like swimming pools, rivers or fish farms.

Cappelli, I., Fort, A., Mugnaini, M., Parrino, S., Pozzebon, A. (2020). Underwater to above water LoRa transmission: Technical issues and preliminary tests. In 24th IMEKO TC4 International Symposium and 22nd International Workshop on ADC and DAC Modelling and Testing (pp.96-101). International Measurement Confederation (IMEKO).

Underwater to above water LoRa transmission: Technical issues and preliminary tests

Cappelli, I.;Fort, A.;Mugnaini, M.;Parrino, S.;Pozzebon, A.
2020-01-01

Abstract

The aim of this paper is to discuss the usability of Long Range (LoRa) communication technology for the transmission of data collected under fresh water to a Gateway positioned outside water. The technical feasibility of the LoRa transmission channel is discussed from a theoretical point of view, focusing on the definition of the link budget for the proposed scenario. The operation of a prototypal LoRa sensor node is then tested in a real scenario, analyzing the performances according to the different Spreading Factors (SF). Actual data transmission is achieved at a depth of 30 cm, thus suggesting the usage of such a technology for real time monitoring applications in environments, like swimming pools, rivers or fish farms.
2020
Cappelli, I., Fort, A., Mugnaini, M., Parrino, S., Pozzebon, A. (2020). Underwater to above water LoRa transmission: Technical issues and preliminary tests. In 24th IMEKO TC4 International Symposium and 22nd International Workshop on ADC and DAC Modelling and Testing (pp.96-101). International Measurement Confederation (IMEKO).
File in questo prodotto:
File Dimensione Formato  
IMEKO-TC4-2020-19.pdf

accesso aperto

Tipologia: PDF editoriale
Licenza: PUBBLICO - Pubblico con Copyright
Dimensione 345.8 kB
Formato Adobe PDF
345.8 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/1177933