The CREAM calorimeter, designed to measure the spectra of cosmic-ray nuclei from under 1 TeV to 1000 TeV, is a 20 radiation length (X-0) deep sampling calorimeter. The calorimeter is comprised of 20 layers of tungsten interleaved with 20 layers of scintillating fiber ribbons, and is preceded by a pair of graphite interaction targets providing about 0.42 proton interaction lengths (lambda(int)). The calorimeter was placed in one of CERN's SPS accelerator beams for calibration and testing. Beams of 150 GeV electrons were used for calibration, and a variety of electron, proton, and nuclear fragment beams were used to test the simulation model of the detector. In this paper we discuss the performance of the calorimeter in the electron beam and compare electron beam data with simulation results.

Y. S., Y., H. S., A., M. G., B., Bigongiari, G., O., G., J. H., H., et al. (2005). Performance of the CREAM calorimeter in accelerator beam test. In Proceedings of the 29th International Cosmic Ray Conference (pp.371-374). Pune : Tata Inst Fundamental Research.

Performance of the CREAM calorimeter in accelerator beam test

BIGONGIARI, GABRIELE;MAESTRO, PAOLO;MARROCCHESI, PIER SIMONE;
2005-01-01

Abstract

The CREAM calorimeter, designed to measure the spectra of cosmic-ray nuclei from under 1 TeV to 1000 TeV, is a 20 radiation length (X-0) deep sampling calorimeter. The calorimeter is comprised of 20 layers of tungsten interleaved with 20 layers of scintillating fiber ribbons, and is preceded by a pair of graphite interaction targets providing about 0.42 proton interaction lengths (lambda(int)). The calorimeter was placed in one of CERN's SPS accelerator beams for calibration and testing. Beams of 150 GeV electrons were used for calibration, and a variety of electron, proton, and nuclear fragment beams were used to test the simulation model of the detector. In this paper we discuss the performance of the calorimeter in the electron beam and compare electron beam data with simulation results.
2005
Y. S., Y., H. S., A., M. G., B., Bigongiari, G., O., G., J. H., H., et al. (2005). Performance of the CREAM calorimeter in accelerator beam test. In Proceedings of the 29th International Cosmic Ray Conference (pp.371-374). Pune : Tata Inst Fundamental Research.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/43250
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo