BACKGROUND: The introduction of resonance frequency analysis (RFA) as a commercially available technique has made it possible to measure implant stability in implant stability quotient (ISQ) units at any time during the course of implant treatment and loading. However, no information on normal ISQ levels can be found in the literature. PURPOSE: The aim of this pilot study was to measure the stability of clinically successful implants in partially edentulous patients after 1 year of loading and to study the influence of jaw, anterior/posterior position, implant length, and marginal bone level on implant stability. MATERIALS AND METHODS: Fourteen partially edentulous patients previously treated with 45 implants were subjected to clinical and radiographic evaluations and RFA measurements using Osstell (Integration Diagnostics, Savedalen, Sweden) after 1 year of loading. RESULTS: All 45 implants were stable, and implant stability levels were in the range of 57 to 82 ISQ units with a mean of 69 +/- 6.5 ISQ after 1 year of loading. Mandibular implants were more stable than were maxillary ones. There were no differences between anterior and posterior implants. No correlation could be found between implant length and stability. Only minor marginal bone resorption was observed. CONCLUSIONS: The results from this limited material showed that successfully integrated implants have ISQ levels from 57 to 82 ISQ with a mean of 69 ISQ after 1 year of loading. Mandibular implants are more stable than are maxillary ones. High implant stability can be achieved with short implants and placement in posterior regions.

Balleri, P., Cozzolino, A., Ghelli, L.F., Momicchioli, G., Variale, A. (2002). Stability measuraments of osseointegrated implants using OSSTELL in partially edentulous jaws after 1 year of loading: a pilot study. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 4(3), 128-132 [10.1111/j.1708-8208.2002.tb00162.x].

Stability measuraments of osseointegrated implants using OSSTELL in partially edentulous jaws after 1 year of loading: a pilot study

BALLERI P.;
2002-01-01

Abstract

BACKGROUND: The introduction of resonance frequency analysis (RFA) as a commercially available technique has made it possible to measure implant stability in implant stability quotient (ISQ) units at any time during the course of implant treatment and loading. However, no information on normal ISQ levels can be found in the literature. PURPOSE: The aim of this pilot study was to measure the stability of clinically successful implants in partially edentulous patients after 1 year of loading and to study the influence of jaw, anterior/posterior position, implant length, and marginal bone level on implant stability. MATERIALS AND METHODS: Fourteen partially edentulous patients previously treated with 45 implants were subjected to clinical and radiographic evaluations and RFA measurements using Osstell (Integration Diagnostics, Savedalen, Sweden) after 1 year of loading. RESULTS: All 45 implants were stable, and implant stability levels were in the range of 57 to 82 ISQ units with a mean of 69 +/- 6.5 ISQ after 1 year of loading. Mandibular implants were more stable than were maxillary ones. There were no differences between anterior and posterior implants. No correlation could be found between implant length and stability. Only minor marginal bone resorption was observed. CONCLUSIONS: The results from this limited material showed that successfully integrated implants have ISQ levels from 57 to 82 ISQ with a mean of 69 ISQ after 1 year of loading. Mandibular implants are more stable than are maxillary ones. High implant stability can be achieved with short implants and placement in posterior regions.
2002
Balleri, P., Cozzolino, A., Ghelli, L.F., Momicchioli, G., Variale, A. (2002). Stability measuraments of osseointegrated implants using OSSTELL in partially edentulous jaws after 1 year of loading: a pilot study. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 4(3), 128-132 [10.1111/j.1708-8208.2002.tb00162.x].
File in questo prodotto:
File Dimensione Formato  
stability-measurements-osseointegrated-2002.pdf

non disponibili

Descrizione: Articolo
Tipologia: PDF editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 776.59 kB
Formato Adobe PDF
776.59 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/399787
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo