BACKGROUND: We compared telecare and conventional self-monitored blood glucose (SMBG) programs for titrating the addition of one bolus injection of insulin glulisine in patients with type 2 diabetes uncontrolled on oral hypoglycemic agents for ≥3 months who were first titrated with basal insulin glargine. METHODS: This randomized, multicenter, parallel-group study included 241 patients (mean screening glycosylated hemoglobin [HbA(1c)], 8.8% [73 mmol/mol]). In the run-in phase, any antidiabetes medication, except for metformin, was discontinued. Metformin was then up-titrated to 2 g/day (1 g twice daily) until study completion. Following run-in, all patients started glargine for 8-16 weeks, targeting fasting plasma glucose (FPG) ≤5.6 mmol/L using conventional SMBG. Patients with FPG ≤7 mmol/L added a glulisine dose at the meal with the highest postprandial plasma glucose excursion, titrated to target 2-h postprandial plasma glucose level <7.8 mmol/L using telecare or SMBG for 24 weeks. Patients with FPG >7 mmol/L at week 16 were withdrawn from the study. RESULTS: After glargine titration, 224 patients achieved FPG ≤7 mmol/L, without any difference between telecare and SBMG groups (mean±SD, 6.2±0.8 vs. 6.0±0. 9 mmol/L, respectively). HbA(1c) levels were lower following titration and were similar for telecare and SMBG (7.9±0.9% vs. 7.8±0.9% [63 vs. 62 mmol/mol], respectively). Adding glulisine further reduced HbA(1c) in both groups (-0.7% vs. -0.7%); 45.2% and 54.8% (P=0.14), respectively, of patients achieved HbA(1c) ≤7.0% (≤53 mmol/mol). Weight change and hypoglycemia were similar between groups. CONCLUSIONS: Patients adding one dose of glulisine at the meal with the highest postprandial plasma glucose excursion to titrated basal glargine achieved comparable improvements in glycemic control irrespective of traditional or telecare blood glucose monitoring.

Del Prato, S., Nicolucci, A., Lovagnini-Scher, A., Turco, S., Leotta, S., Vespasiani, G., et al. (2012). Telecare Provides comparable efficacy to conventional self-monitored blood glucose in patients with type 2 diabetes titrating one injection of insulin glulisine-the ELEONOR study. DIABETES TECHNOLOGY & THERAPEUTICS, 14(2), 175-182 [10.1089/dia.2011.0163].

Telecare Provides comparable efficacy to conventional self-monitored blood glucose in patients with type 2 diabetes titrating one injection of insulin glulisine-the ELEONOR study

Dotta F.;
2012-01-01

Abstract

BACKGROUND: We compared telecare and conventional self-monitored blood glucose (SMBG) programs for titrating the addition of one bolus injection of insulin glulisine in patients with type 2 diabetes uncontrolled on oral hypoglycemic agents for ≥3 months who were first titrated with basal insulin glargine. METHODS: This randomized, multicenter, parallel-group study included 241 patients (mean screening glycosylated hemoglobin [HbA(1c)], 8.8% [73 mmol/mol]). In the run-in phase, any antidiabetes medication, except for metformin, was discontinued. Metformin was then up-titrated to 2 g/day (1 g twice daily) until study completion. Following run-in, all patients started glargine for 8-16 weeks, targeting fasting plasma glucose (FPG) ≤5.6 mmol/L using conventional SMBG. Patients with FPG ≤7 mmol/L added a glulisine dose at the meal with the highest postprandial plasma glucose excursion, titrated to target 2-h postprandial plasma glucose level <7.8 mmol/L using telecare or SMBG for 24 weeks. Patients with FPG >7 mmol/L at week 16 were withdrawn from the study. RESULTS: After glargine titration, 224 patients achieved FPG ≤7 mmol/L, without any difference between telecare and SBMG groups (mean±SD, 6.2±0.8 vs. 6.0±0. 9 mmol/L, respectively). HbA(1c) levels were lower following titration and were similar for telecare and SMBG (7.9±0.9% vs. 7.8±0.9% [63 vs. 62 mmol/mol], respectively). Adding glulisine further reduced HbA(1c) in both groups (-0.7% vs. -0.7%); 45.2% and 54.8% (P=0.14), respectively, of patients achieved HbA(1c) ≤7.0% (≤53 mmol/mol). Weight change and hypoglycemia were similar between groups. CONCLUSIONS: Patients adding one dose of glulisine at the meal with the highest postprandial plasma glucose excursion to titrated basal glargine achieved comparable improvements in glycemic control irrespective of traditional or telecare blood glucose monitoring.
2012
Del Prato, S., Nicolucci, A., Lovagnini-Scher, A., Turco, S., Leotta, S., Vespasiani, G., et al. (2012). Telecare Provides comparable efficacy to conventional self-monitored blood glucose in patients with type 2 diabetes titrating one injection of insulin glulisine-the ELEONOR study. DIABETES TECHNOLOGY & THERAPEUTICS, 14(2), 175-182 [10.1089/dia.2011.0163].
File in questo prodotto:
File Dimensione Formato  
2012 Del Prato et al Diabetes Technol Ther.pdf

non disponibili

Tipologia: PDF editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 371.16 kB
Formato Adobe PDF
371.16 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/39349
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo