To improve the measurement resolution of the fetalheartrate (FHR) beat-to-beat variation, which is an important prognostic indicator of fetal well-being. Method: The goal was reached using an autoregressive (AR) approach, instead of conventional algorithms based on the Fast Fourier Transform (FFT), for the analysis of the umbilicalarteryDopplersignals. Results: The resolution improvement obtainable with the proposed technique in the FHR beat-to-beat variation was proved both with simulation and with experimental results. The method was implemented in a personal computer (PC) based equipment which works in a quasi-real time mode. Conclusions: The proposed technique can be usefully applied to the FHR beat-to-beat variation measurements; the developed prototype is at present used for clinical practice at the 'Clinica Ostetrica e Ginecologica' of the University of Firenze.

Fort, A., Masotti, L., Rocchi, S., Vignoli, V., DI TOMMASO, M., Consoli, C., et al. (1995). Parametric spectral analysis of umbilical artery Doppler signals for fetal heart rate variability evaluation. EUROPEAN JOURNAL OF ULTRASOUND, 2(4), 321-328 [10.1016/0929-8266(95)00122-8].

Parametric spectral analysis of umbilical artery Doppler signals for fetal heart rate variability evaluation.

FORT, ADA;ROCCHI, SANTINA;VIGNOLI, VALERIO;
1995-01-01

Abstract

To improve the measurement resolution of the fetalheartrate (FHR) beat-to-beat variation, which is an important prognostic indicator of fetal well-being. Method: The goal was reached using an autoregressive (AR) approach, instead of conventional algorithms based on the Fast Fourier Transform (FFT), for the analysis of the umbilicalarteryDopplersignals. Results: The resolution improvement obtainable with the proposed technique in the FHR beat-to-beat variation was proved both with simulation and with experimental results. The method was implemented in a personal computer (PC) based equipment which works in a quasi-real time mode. Conclusions: The proposed technique can be usefully applied to the FHR beat-to-beat variation measurements; the developed prototype is at present used for clinical practice at the 'Clinica Ostetrica e Ginecologica' of the University of Firenze.
1995
Fort, A., Masotti, L., Rocchi, S., Vignoli, V., DI TOMMASO, M., Consoli, C., et al. (1995). Parametric spectral analysis of umbilical artery Doppler signals for fetal heart rate variability evaluation. EUROPEAN JOURNAL OF ULTRASOUND, 2(4), 321-328 [10.1016/0929-8266(95)00122-8].
File in questo prodotto:
File Dimensione Formato  
J3.pdf

non disponibili

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 492.36 kB
Formato Adobe PDF
492.36 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/34810
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo