PURPOSE: To measure the actual dose of triamcinolone acetonide (TA) delivered during intravitreal injection performed by several common techniques. DESIGN: Experimental study. METHODS: A 0.1-ml, 40-mg vial of TA (Kenalog-40; Bristol-Myers-Squibb, Peapack, New Jersey, USA) was prepared according to one of four protocols and the mass determined after drying overnight on waxed paper. In group 1, a 0.1-ml aliquot of TA was dispensed with a 30-gauge needle after shaking the vial 10 or 30 times. Group 2 used a 27-gauge needle. In group 3, the supernatant was removed from the crystals. Group 4 passed the suspension through a 0.2-microm micropore filter and rinsed the crystals with saline. RESULTS: There was no statistically significant difference between 30- or 27-gauge needles (P = 0.83, t test) or between shaking the vial 10 or 30 times before withdrawing the drug (P = 0.99). A statistically significant difference (t test, P = 0.001) was found between TA delivered from the initial 60% of each syringe (mean +/- SD, 2.7 +/- 1.0 mg) to that drawn from the last 40% of each syringe (7.8 +/- 3.6 mg). Group 3 had a mean weight of 32.1 +/- 7.0 mg and group 4, 10.6 +/- 2.1 mg. CONCLUSIONS: Efforts to achieve a 4.0-mg dose of TA, regardless of method used, are variable and inconsistent. Injecting through a small-gauge needle appears to concentrate the remaining suspension. Techniques to concentrate TA or remove aqueous preservatives by filtering effectively increase the concentration, but these results are variable.

Ober, M.d., Barile, G.r., Tari, S.r., Tosi, G.M., Schiff, W.m., Chang, S. (2006). Measurement of the actual dose of triamcinolone acetonide delivered by common techniques of intravitreal injection. AMERICAN JOURNAL OF OPHTHALMOLOGY, 142(4), 597-600 [10.1016/j.ajo.2006.05.041].

Measurement of the actual dose of triamcinolone acetonide delivered by common techniques of intravitreal injection.

TOSI, GIAN MARCO;
2006-01-01

Abstract

PURPOSE: To measure the actual dose of triamcinolone acetonide (TA) delivered during intravitreal injection performed by several common techniques. DESIGN: Experimental study. METHODS: A 0.1-ml, 40-mg vial of TA (Kenalog-40; Bristol-Myers-Squibb, Peapack, New Jersey, USA) was prepared according to one of four protocols and the mass determined after drying overnight on waxed paper. In group 1, a 0.1-ml aliquot of TA was dispensed with a 30-gauge needle after shaking the vial 10 or 30 times. Group 2 used a 27-gauge needle. In group 3, the supernatant was removed from the crystals. Group 4 passed the suspension through a 0.2-microm micropore filter and rinsed the crystals with saline. RESULTS: There was no statistically significant difference between 30- or 27-gauge needles (P = 0.83, t test) or between shaking the vial 10 or 30 times before withdrawing the drug (P = 0.99). A statistically significant difference (t test, P = 0.001) was found between TA delivered from the initial 60% of each syringe (mean +/- SD, 2.7 +/- 1.0 mg) to that drawn from the last 40% of each syringe (7.8 +/- 3.6 mg). Group 3 had a mean weight of 32.1 +/- 7.0 mg and group 4, 10.6 +/- 2.1 mg. CONCLUSIONS: Efforts to achieve a 4.0-mg dose of TA, regardless of method used, are variable and inconsistent. Injecting through a small-gauge needle appears to concentrate the remaining suspension. Techniques to concentrate TA or remove aqueous preservatives by filtering effectively increase the concentration, but these results are variable.
2006
Ober, M.d., Barile, G.r., Tari, S.r., Tosi, G.M., Schiff, W.m., Chang, S. (2006). Measurement of the actual dose of triamcinolone acetonide delivered by common techniques of intravitreal injection. AMERICAN JOURNAL OF OPHTHALMOLOGY, 142(4), 597-600 [10.1016/j.ajo.2006.05.041].
File in questo prodotto:
File Dimensione Formato  
Measurement-of.pdf

non disponibili

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 427.99 kB
Formato Adobe PDF
427.99 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/25551
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo