PURPOSE:The aim of this study was to evaluate reproducibility of a fast MRI protocol to measure gastric emptying and motility of the gastric antrum. METHODS AND MATERIALS: Gastric emptying and antral speed were measured in 12 type 1 diabetic patients (mean age 43 years) and 9 healthy volunteers (mean age 31 years). Subjects, fasting from 6h, were evaluated in supine position using a 1.5T MR scanner and a eight-channels phased-array body coil after ingestion of 400 ml of a vanillas pudding mixed with 5 ml of Gd-DTPA. Axial 3D T1w sequence at 0 and 30 min for volume evaluation and cine-steady state acquisition every 5 min for a total time of 30 min for gastric wave speed assessing were acquired. Two blinded observers extrapolated T(1/2) from gastric volume assessment and speed of gastric waves. RESULTS: All the patients tolerated the examination. The T(1/2) cut-off was of 115 min with an accuracy in differentiate controls from diabetics of 96% (95% CI 0.766-0.992; p<0.001), while the antral speed cut-off was of 0.15 mm/s with an accuracy of 87% (95% CI 0.628-0.977; p<0.001). The inter-observer agreement for the volumes at time 0 and 30 min was respectively 0.983 (95% CI 0.9628-0.9929; p<0.001) and 0.9933 (95% CI 0.9847-0.9971; p<0.001) with an agreement of 0.9918 (95% CI 0.9853-0.9954; p<0.001), while for antral speed it was of 0.935 (95% CI 0.9097-0.9528; p<0.001). CONCLUSIONS: MRI is a reproducible technique for the evaluation of gastric emptying and antral motility. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

Carbone, S.F., Tanganelli, I., Capodivento, S., Ricci, V., Volterrani, L. (2010). Magnetic resonance imaging in the evaluation of the gastric emptying and antral motion: feasibility and reproducibility of a fast not invasive technique. EUROPEAN JOURNAL OF RADIOLOGY, 75(2), 212-214 [10.1016/j.ejrad.2009.04.071].

Magnetic resonance imaging in the evaluation of the gastric emptying and antral motion: feasibility and reproducibility of a fast not invasive technique

Tanganelli I.;Volterrani L.
2010-01-01

Abstract

PURPOSE:The aim of this study was to evaluate reproducibility of a fast MRI protocol to measure gastric emptying and motility of the gastric antrum. METHODS AND MATERIALS: Gastric emptying and antral speed were measured in 12 type 1 diabetic patients (mean age 43 years) and 9 healthy volunteers (mean age 31 years). Subjects, fasting from 6h, were evaluated in supine position using a 1.5T MR scanner and a eight-channels phased-array body coil after ingestion of 400 ml of a vanillas pudding mixed with 5 ml of Gd-DTPA. Axial 3D T1w sequence at 0 and 30 min for volume evaluation and cine-steady state acquisition every 5 min for a total time of 30 min for gastric wave speed assessing were acquired. Two blinded observers extrapolated T(1/2) from gastric volume assessment and speed of gastric waves. RESULTS: All the patients tolerated the examination. The T(1/2) cut-off was of 115 min with an accuracy in differentiate controls from diabetics of 96% (95% CI 0.766-0.992; p<0.001), while the antral speed cut-off was of 0.15 mm/s with an accuracy of 87% (95% CI 0.628-0.977; p<0.001). The inter-observer agreement for the volumes at time 0 and 30 min was respectively 0.983 (95% CI 0.9628-0.9929; p<0.001) and 0.9933 (95% CI 0.9847-0.9971; p<0.001) with an agreement of 0.9918 (95% CI 0.9853-0.9954; p<0.001), while for antral speed it was of 0.935 (95% CI 0.9097-0.9528; p<0.001). CONCLUSIONS: MRI is a reproducible technique for the evaluation of gastric emptying and antral motility. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.
2010
Carbone, S.F., Tanganelli, I., Capodivento, S., Ricci, V., Volterrani, L. (2010). Magnetic resonance imaging in the evaluation of the gastric emptying and antral motion: feasibility and reproducibility of a fast not invasive technique. EUROPEAN JOURNAL OF RADIOLOGY, 75(2), 212-214 [10.1016/j.ejrad.2009.04.071].
File in questo prodotto:
File Dimensione Formato  
Magnetic resonance imaging in the evaluation of the gastric emptying and antralVOLT.pdf

non disponibili

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 233.26 kB
Formato Adobe PDF
233.26 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/24747
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo