The objective of this study was to compare population pharmacokinetic models of escitalopram developed from dosage times recorded by a medication event monitoring system (MEMS) versus the reported times from patients with diagnosed depression. Seventy-three patients were prescribed doses of 10, 15, or 20 mg escitalopram daily. Sparse blood samples were collected at weeks 4, 12, 24, and 36 with 185 blood samples obtained from the 73 patients. NONMEM was used to develop a population pharmacokinetic model based on dosing records obtained from MEMS prior to each blood sample time. A separate population pharmacokinetic analysis using NONMEM was performed for the same population using the patient-reported last dosing time and assuming a steady-state condition as the model input. Objective function values and goodness-of-fit plots were used as model selection criteria. The absolute mean difference in the last dosing time between MEMS and patient-reported times was 4.48 ± 10.12 hours. A 1-compartment model with first-order absorption and elimination was sufficient for describing the data. Estimated oral clearance (CL/F) to escitalopram was statistically insensitive to reported dosing methods (MEMS vs patient reported: 25.5 [7.0%] vs 26.9 [6.6%] L/h). However, different dosing report methods resulted in significantly different estimates on the volume of distribution (V/F; MEMS vs patient reported: 1000 [17.3%] vs 767 [17.5%] L) and the absorption rate constant Ka (MEMS vs patient reported: 0.74 [45.7%] vs 0.51 [35.4%] h-1) for escitalopram. Furthermore, the parameters estimated from the MEMS method were similar to literature reported values for V/F (∼1100 L) and Ka (∼0.8-0.9 h-1) arising from traditional pharmacokinetic approaches. © 2009 the American College of Clinical Pharmacology.

Jin, Y., Pollock, B.G., Frank, E., Florian, J., Kirshner, M., Fagiolini, A., et al. (2009). The effect of reporting methods for dosing times on the estimation of pharmacokinetic parameters of escitalopram. THE JOURNAL OF CLINICAL PHARMACOLOGY, 49(2), 176-184 [10.1177/0091270008327538].

The effect of reporting methods for dosing times on the estimation of pharmacokinetic parameters of escitalopram

FAGIOLINI, A.;
2009-01-01

Abstract

The objective of this study was to compare population pharmacokinetic models of escitalopram developed from dosage times recorded by a medication event monitoring system (MEMS) versus the reported times from patients with diagnosed depression. Seventy-three patients were prescribed doses of 10, 15, or 20 mg escitalopram daily. Sparse blood samples were collected at weeks 4, 12, 24, and 36 with 185 blood samples obtained from the 73 patients. NONMEM was used to develop a population pharmacokinetic model based on dosing records obtained from MEMS prior to each blood sample time. A separate population pharmacokinetic analysis using NONMEM was performed for the same population using the patient-reported last dosing time and assuming a steady-state condition as the model input. Objective function values and goodness-of-fit plots were used as model selection criteria. The absolute mean difference in the last dosing time between MEMS and patient-reported times was 4.48 ± 10.12 hours. A 1-compartment model with first-order absorption and elimination was sufficient for describing the data. Estimated oral clearance (CL/F) to escitalopram was statistically insensitive to reported dosing methods (MEMS vs patient reported: 25.5 [7.0%] vs 26.9 [6.6%] L/h). However, different dosing report methods resulted in significantly different estimates on the volume of distribution (V/F; MEMS vs patient reported: 1000 [17.3%] vs 767 [17.5%] L) and the absorption rate constant Ka (MEMS vs patient reported: 0.74 [45.7%] vs 0.51 [35.4%] h-1) for escitalopram. Furthermore, the parameters estimated from the MEMS method were similar to literature reported values for V/F (∼1100 L) and Ka (∼0.8-0.9 h-1) arising from traditional pharmacokinetic approaches. © 2009 the American College of Clinical Pharmacology.
2009
Jin, Y., Pollock, B.G., Frank, E., Florian, J., Kirshner, M., Fagiolini, A., et al. (2009). The effect of reporting methods for dosing times on the estimation of pharmacokinetic parameters of escitalopram. THE JOURNAL OF CLINICAL PHARMACOLOGY, 49(2), 176-184 [10.1177/0091270008327538].
File in questo prodotto:
File Dimensione Formato  
The_Effect_of_Reporting_Methods_for_Dosing_Times_on_the_Estimation_of_Pharmacokinetic_Parameters_of_Escitalopram.pdf

non disponibili

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 394.04 kB
Formato Adobe PDF
394.04 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/12118
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo