PURPOSE: The purpose of this study was to test the reproducibility of the three-dimensional (3D) Advanced Lung Analysis software (3D-ALA, GE Healthcare) in the estimation of pulmonary nodule volume. MATERIALS AND METHODS: We retrospectively reviewed the unenhanced multislice CT scans (Lightspeed Pro 16 GE) of 77 patients with a solitary pulmonary nodule (n=71) or metastatic pulmonary disease (n=6). A total of 103 pulmonary nodules (19 well-circumscribed, 45 juxtavascular and 39 juxtapleural) were analysed grouped into five classes based on diameter: <5 mm, 10 nodules (9.7%); >or=5 to <10 mm, 25 nodules (24.2%); >or=10 mm to <15 mm, 41 nodules (39.8%); >or=5 to <18 mm, 14 nodules (13.6% ); >or=8 to <30 mm, 13 nodules (12.62%). The following acquisition parameters were used: slice thickness 0.625 mm, reconstruction interval 0.4 mm, pitch 0.562:1, 140 kV, 300 mAs, field of view 13 cm, bone kernel. For each of the 103 nodules three, 3D volume measurements were obtained by the 3D-ALA software. The reproducibility of nodule segmentation was evaluated according to a visual score (1=optimal, >or=95%; 2=fair, 90-95%; 3=poor, 0.05). CONCLUSIONS: Three-dimensional volume measurement with ALARiassunto 1 software is reproducible for all nodules as regards dimension and site. ALA-1 software provided a good and reproducible volume measurement in well-circumscribed and most juxtavascular nodules. Volumetric evaluation and reproducibility of volume estimation in juxtapleural pulmonary nodules, particularly those adjacent to diaphragmatic pleura, is inadequate, and software improvement is needed

Volterrani, L., Mazzei, M.A., Scialpi, M., Carcano, M., Carbone, S.F., Ricci, V., et al. (2006). Three-dimensional analysis of pulmonary nodules by MSCT with Advanced Lung Analysis (ALA1) software [Analisi volumetrica tridimensionale mediante TCMS con software Advanced Lung Analysis (ALA1) del nodulo polmonare]. LA RADIOLOGIA MEDICA, 111(3), 343-354 [10.1007/s11547-006-0033-4].

Three-dimensional analysis of pulmonary nodules by MSCT with Advanced Lung Analysis (ALA1) software [Analisi volumetrica tridimensionale mediante TCMS con software Advanced Lung Analysis (ALA1) del nodulo polmonare]

VOLTERRANI L.;MAZZEI M. A.;
2006-01-01

Abstract

PURPOSE: The purpose of this study was to test the reproducibility of the three-dimensional (3D) Advanced Lung Analysis software (3D-ALA, GE Healthcare) in the estimation of pulmonary nodule volume. MATERIALS AND METHODS: We retrospectively reviewed the unenhanced multislice CT scans (Lightspeed Pro 16 GE) of 77 patients with a solitary pulmonary nodule (n=71) or metastatic pulmonary disease (n=6). A total of 103 pulmonary nodules (19 well-circumscribed, 45 juxtavascular and 39 juxtapleural) were analysed grouped into five classes based on diameter: <5 mm, 10 nodules (9.7%); >or=5 to <10 mm, 25 nodules (24.2%); >or=10 mm to <15 mm, 41 nodules (39.8%); >or=5 to <18 mm, 14 nodules (13.6% ); >or=8 to <30 mm, 13 nodules (12.62%). The following acquisition parameters were used: slice thickness 0.625 mm, reconstruction interval 0.4 mm, pitch 0.562:1, 140 kV, 300 mAs, field of view 13 cm, bone kernel. For each of the 103 nodules three, 3D volume measurements were obtained by the 3D-ALA software. The reproducibility of nodule segmentation was evaluated according to a visual score (1=optimal, >or=95%; 2=fair, 90-95%; 3=poor, 0.05). CONCLUSIONS: Three-dimensional volume measurement with ALARiassunto 1 software is reproducible for all nodules as regards dimension and site. ALA-1 software provided a good and reproducible volume measurement in well-circumscribed and most juxtavascular nodules. Volumetric evaluation and reproducibility of volume estimation in juxtapleural pulmonary nodules, particularly those adjacent to diaphragmatic pleura, is inadequate, and software improvement is needed
2006
Volterrani, L., Mazzei, M.A., Scialpi, M., Carcano, M., Carbone, S.F., Ricci, V., et al. (2006). Three-dimensional analysis of pulmonary nodules by MSCT with Advanced Lung Analysis (ALA1) software [Analisi volumetrica tridimensionale mediante TCMS con software Advanced Lung Analysis (ALA1) del nodulo polmonare]. LA RADIOLOGIA MEDICA, 111(3), 343-354 [10.1007/s11547-006-0033-4].
File in questo prodotto:
File Dimensione Formato  
Three-dimensional analysis of pulmonary nodules.pdf

non disponibili

Tipologia: Abstract
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.1 MB
Formato Adobe PDF
1.1 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/12095
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo