Introduction: Management of breast abscess in lactating women remains controversial. During pregnancy, women may develop different kinds of benign breast lesions that could require a surgical incision performed under general anesthesia with consequent breastfeeding interruption. The purpose of this study was to prospectively evaluate the management of large breast abscesses with ultrasound-assisted drainage aiming at breastfeeding preservation. Materials and Methods: 34 lactating women with a diagnosis of unilateral breast abscess have been treated with an ultrasound (US)-assisted drainage of the abscess. A pigtail catheter was inserted into the fluid collection using the Seldinger technique under US guide and connected to a three stop way to allow drainage and irrigation of the cavity until its resolution. Results: All procedures have been found safe and well tolerated. No recurrence was observed and breastfeeding was never interrupted. Conclusions: The described technique allows to avoid surgery and to preserve breastfeeding in well-selected patients with a safe, well-tolerated and cost-effective procedure.
Falco, G., Foroni, M., Castagnetti, F., Marano, L., Bordoni, D., Rocco, N., et al. (2016). Ultrasound-Guided Percutaneous Catheter Drainage of Large Breast Abscesses in Lactating Women: How to Preserve Breastfeeding Safely. BREASTFEEDING MEDICINE, 11(10), 555-556 [10.1089/bfm.2016.0121].
Ultrasound-Guided Percutaneous Catheter Drainage of Large Breast Abscesses in Lactating Women: How to Preserve Breastfeeding Safely
Marano, Luigi;
2016-01-01
Abstract
Introduction: Management of breast abscess in lactating women remains controversial. During pregnancy, women may develop different kinds of benign breast lesions that could require a surgical incision performed under general anesthesia with consequent breastfeeding interruption. The purpose of this study was to prospectively evaluate the management of large breast abscesses with ultrasound-assisted drainage aiming at breastfeeding preservation. Materials and Methods: 34 lactating women with a diagnosis of unilateral breast abscess have been treated with an ultrasound (US)-assisted drainage of the abscess. A pigtail catheter was inserted into the fluid collection using the Seldinger technique under US guide and connected to a three stop way to allow drainage and irrigation of the cavity until its resolution. Results: All procedures have been found safe and well tolerated. No recurrence was observed and breastfeeding was never interrupted. Conclusions: The described technique allows to avoid surgery and to preserve breastfeeding in well-selected patients with a safe, well-tolerated and cost-effective procedure.File | Dimensione | Formato | |
---|---|---|---|
Breastfeeding paper.pdf
non disponibili
Tipologia:
PDF editoriale
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
62.08 kB
Formato
Adobe PDF
|
62.08 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11365/1067144